Search
- 1
- 2
-
-
Overview
Lifegard Aquatics introduces the Pro-MAX™ UV Sterilizer, featuring a patent-pending, flow-through design with less restrictive angled inlet and outlet ports requiring less plumbing. This unique design enables easy installation of new or replacement systems as it can be positioned in multiple ways to fit any tight space. Available with 3″ housing in 25, 40, 55, 90 and 120 Watt models and 5″ housing in 55, 90 and 120 Watt sizes. Each Pro-MAX™ features a High Output UV Bulb, Internal Protective Sleeve, and UL Listed Ballast which counts down the number of days until you need to replace the bulb. Maximum Operating Pressure 30 PSI.
334 -
Overview
For Submersible or Dry Applications in Salt or Freshwater Aquariums.
- Extremely quiet operation…so quiet you’ll swear it’s not running.
- Safe for Salt or Freshwater applications.
- Use with all types of filters. Includes 6’cord.
- ECO-SAV™ runs cooler and generates more power with less energy consumption.
- Internal recirculation prevents overheating and ejects obstructing debris.
- Remarkable impeller technology provides combined rotors, improved shaft materials and corrosion resistant bearings.
- EZ access cover allows ease of maintenance of rotor, shaft and removable impellers.
- Innovative “cooling chambers” provide air-cooling during dry use and water-cooling in wet applications.
- Pre-filter Grill with Flow Control Valve in submersible applications.
- Flow Controls on 200,400, 800,1200,2200,3000,4000,5000 and 6000 Models.
- 120V/60HZ 230V/50HZ models available
369 -
Overview
For Submersible or Dry Applications in Salt or Freshwater Aquariums.
- Extremely quiet operation…so quiet you’ll swear it’s not running.
- Safe for Salt or Freshwater applications.
- Use with all types of filters. Includes 6’cord.
- ECO-SAV™ runs cooler and generates more power with less energy consumption.
- Internal recirculation prevents overheating and ejects obstructing debris.
- Remarkable impeller technology provides combined rotors, improved shaft materials and corrosion resistant bearings.
- EZ access cover allows ease of maintenance of rotor, shaft and removable impellers.
- Innovative “cooling chambers” provide air-cooling during dry use and water-cooling in wet applications.
- Pre-filter Grill with Flow Control Valve in submersible applications.
- Flow Controls on 200,400, 800,1200,2200,3000,4000,5000 and 6000 Models.
- 120V/60HZ 230V/50HZ models available
392 -
Overview
For Submersible or Dry Applications in Salt or Freshwater Aquariums.
- Extremely quiet operation…so quiet you’ll swear it’s not running.
- Safe for Salt or Freshwater applications.
- Use with all types of filters. Includes 6’cord.
- ECO-SAV™ runs cooler and generates more power with less energy consumption.
- Internal recirculation prevents overheating and ejects obstructing debris.
- Remarkable impeller technology provides combined rotors, improved shaft materials and corrosion resistant bearings.
- EZ access cover allows ease of maintenance of rotor, shaft and removable impellers.
- Innovative “cooling chambers” provide air-cooling during dry use and water-cooling in wet applications.
- Pre-filter Grill with Flow Control Valve in submersible applications.
- Flow Controls on 200,400, 800,1200,2200,3000,4000,5000 and 6000 Models.
- 120V/60HZ 230V/50HZ models available
413 -
Overview
For Submersible or Dry Applications in Salt or Freshwater Aquariums.
- Extremely quiet operation…so quiet you’ll swear it’s not running.
- Safe for Salt or Freshwater applications.
- Use with all types of filters. Includes 6’cord.
- ECO-SAV™ runs cooler and generates more power with less energy consumption.
- Internal recirculation prevents overheating and ejects obstructing debris.
- Remarkable impeller technology provides combined rotors, improved shaft materials and corrosion resistant bearings.
- EZ access cover allows ease of maintenance of rotor, shaft and removable impellers.
- Innovative “cooling chambers” provide air-cooling during dry use and water-cooling in wet applications.
- Pre-filter Grill with Flow Control Valve in submersible applications.
- Flow Controls on 200,400, 800,1200,2200,3000,4000,5000 and 6000 Models.
- 120V/60HZ 230V/50HZ models available
677 -
Overview
For Submersible or Dry Applications in Salt or Freshwater Aquariums.
- Extremely quiet operation…so quiet you’ll swear it’s not running.
- Safe for Salt or Freshwater applications.
- Use with all types of filters. Includes 6’cord.
- ECO-SAV™ runs cooler and generates more power with less energy consumption.
- Internal recirculation prevents overheating and ejects obstructing debris.
- Remarkable impeller technology provides combined rotors, improved shaft materials and corrosion resistant bearings.
- EZ access cover allows ease of maintenance of rotor, shaft and removable impellers.
- Innovative “cooling chambers” provide air-cooling during dry use and water-cooling in wet applications.
- Pre-filter Grill with Flow Control Valve in submersible applications.
- Flow Controls on 200,400, 800,1200,2200,3000,4000,5000 and 6000 Models.
- 120V/60HZ 230V/50HZ models available
711 -
Overview
For Submersible or Dry Applications
- Extremely quite operation… so quiet you’ll swear it’s not running.
- ECO-SAV™ generates more power with less energy consumption.
- Internal recirculation prevents overheating and ejects obstructing debris.
- Remarkable impeller technology provides combined rotors, improved shaft materials and corrosion resistant bearings.
- EZ Access Covers allow ease of maintenance of rotor, shaft and removable impellers.
- Innovative “cooling chambers” provide air-cooling during dry use and water-cooling in wet applications.
- 20′ Cord with grounded plug for indoor/outdoor use.
- 120V/60HZ 230V/50HZ models available.
474 -
Overview
For Submersible or Dry Applications
- Extremely quite operation… so quiet you’ll swear it’s not running.
- ECO-SAV™ generates more power with less energy consumption.
- Internal recirculation prevents overheating and ejects obstructing debris.
- Remarkable impeller technology provides combined rotors, improved shaft materials and corrosion resistant bearings.
- EZ Access Covers allow ease of maintenance of rotor, shaft and removable impellers.
- Innovative “cooling chambers” provide air-cooling during dry use and water-cooling in wet applications.
- 20′ Cord with grounded plug for indoor/outdoor use.
- 120V/60HZ 230V/50HZ models available.
497 -
Overview
For Submersible or Dry Applications
- Extremely quite operation… so quiet you’ll swear it’s not running.
- ECO-SAV™ generates more power with less energy consumption.
- Internal recirculation prevents overheating and ejects obstructing debris.
- Remarkable impeller technology provides combined rotors, improved shaft materials and corrosion resistant bearings.
- EZ Access Covers allow ease of maintenance of rotor, shaft and removable impellers.
- Innovative “cooling chambers” provide air-cooling during dry use and water-cooling in wet applications.
- 20′ Cord with grounded plug for indoor/outdoor use.
- 120V/60HZ 230V/50HZ models available.
518 -
Overview
For Submersible or Dry Applications
- Extremely quite operation… so quiet you’ll swear it’s not running.
- ECO-SAV™ generates more power with less energy consumption.
- Internal recirculation prevents overheating and ejects obstructing debris.
- Remarkable impeller technology provides combined rotors, improved shaft materials and corrosion resistant bearings.
- EZ Access Covers allow ease of maintenance of rotor, shaft and removable impellers.
- Innovative “cooling chambers” provide air-cooling during dry use and water-cooling in wet applications.
- 20′ Cord with grounded plug for indoor/outdoor use.
- 120V/60HZ 230V/50HZ models available.
782 -
Overview
For Submersible or Dry Applications
- Extremely quite operation… so quiet you’ll swear it’s not running.
- ECO-SAV™ generates more power with less energy consumption.
- Internal recirculation prevents overheating and ejects obstructing debris.
- Remarkable impeller technology provides combined rotors, improved shaft materials and corrosion resistant bearings.
- EZ Access Covers allow ease of maintenance of rotor, shaft and removable impellers.
- Innovative “cooling chambers” provide air-cooling during dry use and water-cooling in wet applications.
- 20′ Cord with grounded plug for indoor/outdoor use.
- 120V/60HZ 230V/50HZ models available.
814 -
Overview
Lifegard Aquatics introduces the Pro-MAX™ UV Sterilizer, featuring a patent-pending, flow-through design with less restrictive angled inlet and outlet ports requiring less plumbing. This unique design enables easy installation of new or replacement systems as it can be positioned in multiple ways to fit any tight space. Available with 3″ housing in 25, 40, 55, 90 and 120 Watt models and 5″ housing in 55, 90 and 120 Watt sizes. Each Pro-MAX™ features a High Output UV Bulb, Internal Protective Sleeve, and UL Listed Ballast which counts down the number of days until you need to replace the bulb. Maximum Operating Pressure 30 PSI.
1259 -
Overview
Lifegard Aquatics introduces the Pro-MAX™ UV Sterilizer, featuring a patent-pending, flow-through design with less restrictive angled inlet and outlet ports requiring less plumbing. This unique design enables easy installation of new or replacement systems as it can be positioned in multiple ways to fit any tight space. Available with 3″ housing in 25, 40, 55, 90 and 120 Watt models and 5″ housing in 55, 90 and 120 Watt sizes. Each Pro-MAX™ features a High Output UV Bulb, Internal Protective Sleeve, and UL Listed Ballast which counts down the number of days until you need to replace the bulb. Maximum Operating Pressure 30 PSI.
1602 -
Overview
Lifegard Aquatics introduces the Pro-MAX™ UV Sterilizer, featuring a patent-pending, flow-through design with less restrictive angled inlet and outlet ports requiring less plumbing. This unique design enables easy installation of new or replacement systems as it can be positioned in multiple ways to fit any tight space. Available with 3″ housing in 25, 40, 55, 90 and 120 Watt models and 5″ housing in 55, 90 and 120 Watt sizes. Each Pro-MAX™ features a High Output UV Bulb, Internal Protective Sleeve, and UL Listed Ballast which counts down the number of days until you need to replace the bulb. Maximum Operating Pressure 30 PSI.
1904 -
Overview
Lifegard Aquatics introduces the Pro-MAX™ UV Sterilizer, featuring a patent-pending, flow-through design with less restrictive angled inlet and outlet ports requiring less plumbing. This unique design enables easy installation of new or replacement systems as it can be positioned in multiple ways to fit any tight space. Available with 3″ housing in 25, 40, 55, 90 and 120 Watt models and 5″ housing in 55, 90 and 120 Watt sizes. Each Pro-MAX™ features a High Output UV Bulb, Internal Protective Sleeve, and UL Listed Ballast which counts down the number of days until you need to replace the bulb. Maximum Operating Pressure 30 PSI.
2262 -
Overview
Lifegard Aquatics introduces the Pro-MAX™ UV Sterilizer, featuring a patent-pending, flow-through design with less restrictive angled inlet and outlet ports requiring less plumbing. This unique design enables easy installation of new or replacement systems as it can be positioned in multiple ways to fit any tight space. Available with 3″ housing in 25, 40, 55, 90 and 120 Watt models and 5″ housing in 55, 90 and 120 Watt sizes. Each Pro-MAX™ features a High Output UV Bulb, Internal Protective Sleeve, and UL Listed Ballast which counts down the number of days until you need to replace the bulb. Maximum Operating Pressure 30 PSI.
3667 -
Overview
Lifegard Aquatics introduces the Pro-MAX™ UV Sterilizer, featuring a patent-pending, flow-through design with less restrictive angled inlet and outlet ports requiring less plumbing. This unique design enables easy installation of new or replacement systems as it can be positioned in multiple ways to fit any tight space. Available with 3″ housing in 25, 40, 55, 90 and 120 Watt models and 5″ housing in 55, 90 and 120 Watt sizes. Each Pro-MAX™ features a High Output UV Bulb, Internal Protective Sleeve, and UL Listed Ballast which counts down the number of days until you need to replace the bulb. Maximum Operating Pressure 30 PSI.
2578 -
Overview
Lifegard Aquatics introduces the Pro-MAX™ UV Sterilizer, featuring a patent-pending, flow-through design with less restrictive angled inlet and outlet ports requiring less plumbing. This unique design enables easy installation of new or replacement systems as it can be positioned in multiple ways to fit any tight space. Available with 3″ housing in 25, 40, 55, 90 and 120 Watt models and 5″ housing in 55, 90 and 120 Watt sizes. Each Pro-MAX™ features a High Output UV Bulb, Internal Protective Sleeve, and UL Listed Ballast which counts down the number of days until you need to replace the bulb. Maximum Operating Pressure 30 PSI.
2747 -
Overview
Lifegard Aquatics introduces the Pro-MAX™ UV Sterilizer, featuring a patent-pending, flow-through design with less restrictive angled inlet and outlet ports requiring less plumbing. This unique design enables easy installation of new or replacement systems as it can be positioned in multiple ways to fit any tight space. Available with 3″ housing in 25, 40, 55, 90 and 120 Watt models and 5″ housing in 55, 90 and 120 Watt sizes. Each Pro-MAX™ features a High Output UV Bulb, Internal Protective Sleeve, and UL Listed Ballast which counts down the number of days until you need to replace the bulb. Maximum Operating Pressure 30 PSI.
3699 -
Overview
Lifegard Aquatics introduces the Pro-MAX™ UV Sterilizer, featuring a patent-pending, flow-through design with less restrictive angled inlet and outlet ports requiring less plumbing. This unique design enables easy installation of new or replacement systems as it can be positioned in multiple ways to fit any tight space. Available with 3″ housing in 25, 40, 55, 90 and 120 Watt models and 5″ housing in 55, 90 and 120 Watt sizes. Each Pro-MAX™ features a High Output UV Bulb, Internal Protective Sleeve, and UL Listed Ballast which counts down the number of days until you need to replace the bulb. Maximum Operating Pressure 30 PSI.
384 -
Overview
Lifegard Aquatics introduces the Pro-MAX™ UV Sterilizer, featuring a patent-pending, flow-through design with less restrictive angled inlet and outlet ports requiring less plumbing. This unique design enables easy installation of new or replacement systems as it can be positioned in multiple ways to fit any tight space. Available with 3″ housing in 25, 40, 55, 90 and 120 Watt models and 5″ housing in 55, 90 and 120 Watt sizes. Each Pro-MAX™ features a High Output UV Bulb, Internal Protective Sleeve, and UL Listed Ballast which counts down the number of days until you need to replace the bulb. Maximum Operating Pressure 30 PSI.
479 -
-
Overview
Aquarium, The radiation from ultraviolet light at 2537 angstroms provided inside the Lifegard Ultraviolet Sterilizer exerts a lethal effect on micro-organisms. UV light alters genetic material within the cells, which interrupts respiration. UV light, when used properly, is extremely beneficial in destroying disease causing pathogens as they pass through the unit. UV sterilization is an effective method of disease control. Four major factors affect the percent kill of free-floating micro- organisms by UV radiation. (l) Size of organisms. (2) Radiation level. (3) The extent to which UV rays penetrate the water and (4) Contact time in which the micro-organism is exposed to the UV radiation. Pure hard quartz material in the bulb dramatically increases UV output compared to other conventional bulbs of equal wattage. Pure quartz material resists solarization and improves the longevity of the bulb. Unique test tube style pure hard quartz sleeve isolates the bulb from water contact preventing thermal shock, broken glass and mercury contamination of the aquarium. This quartz sleeve isolates the bulb to provide an optimal bulb operating temperature of 100 degree F(38 degree C). This higher bulb temperature increases UV output 35% over conventional units without sleeves. Bulb changing is the easiest in the industry. Simply slide the old bulb out and slide the new bulb in. No need to shut down the filter system or turn off the pump. Bulb and ballast connect together with a single 4 pin connector. UV radiation levels can be increased by slowing down the flow rate or increasing the total wattage in the system. UV sterilizers are available from 15 watts up to 240 watts. Tandem mounting will provide proper wattage for any installation requirement. UV sterilization is most effective when used as the final stage of the Lifegard filtration system. It must be understood that micro-organisms reproduce exponentially. The goal is to reduce the micro-organism population to an acceptable level. In certain instances, the wattage may be adequate to eliminate the pathogens flowing through the Sterilizer but the flow rate is too slow to keep up with the total micro-organism population in the aquarium system. In those cases, the flow rate and total wattage must be increased.
908 -
Overview
Aquarium, The radiation from ultraviolet light at 2537 angstroms provided inside the Lifegard Ultraviolet Sterilizer exerts a lethal effect on micro-organisms. UV light alters genetic material within the cells, which interrupts respiration. UV light, when used properly, is extremely beneficial in destroying disease causing pathogens as they pass through the unit. UV sterilization is an effective method of disease control. Four major factors affect the percent kill of free-floating micro- organisms by UV radiation. (l) Size of organisms. (2) Radiation level. (3) The extent to which UV rays penetrate the water and (4) Contact time in which the micro-organism is exposed to the UV radiation. Pure hard quartz material in the bulb dramatically increases UV output compared to other conventional bulbs of equal wattage. Pure quartz material resists solarization and improves the longevity of the bulb. Unique test tube style pure hard quartz sleeve isolates the bulb from water contact preventing thermal shock, broken glass and mercury contamination of the aquarium. This quartz sleeve isolates the bulb to provide an optimal bulb operating temperature of 100 degree F(38 degree C). This higher bulb temperature increases UV output 35% over conventional units without sleeves. Bulb changing is the easiest in the industry. Simply slide the old bulb out and slide the new bulb in. No need to shut down the filter system or turn off the pump. Bulb and ballast connect together with a single 4 pin connector. UV radiation levels can be increased by slowing down the flow rate or increasing the total wattage in the system. UV sterilizers are available from 15 watts up to 240 watts. Tandem mounting will provide proper wattage for any installation requirement. UV sterilization is most effective when used as the final stage of the Lifegard filtration system. It must be understood that micro-organisms reproduce exponentially. The goal is to reduce the micro-organism population to an acceptable level. In certain instances, the wattage may be adequate to eliminate the pathogens flowing through the Sterilizer but the flow rate is too slow to keep up with the total micro-organism population in the aquarium system. In those cases, the flow rate and total wattage must be increased.
1124 -
Overview
Aquarium, The radiation from ultraviolet light at 2537 angstroms provided inside the Lifegard Ultraviolet Sterilizer exerts a lethal effect on micro-organisms. UV light alters genetic material within the cells, which interrupts respiration. UV light, when used properly, is extremely beneficial in destroying disease causing pathogens as they pass through the unit. UV sterilization is an effective method of disease control. Four major factors affect the percent kill of free-floating micro- organisms by UV radiation. (l) Size of organisms. (2) Radiation level. (3) The extent to which UV rays penetrate the water and (4) Contact time in which the micro-organism is exposed to the UV radiation. Pure hard quartz material in the bulb dramatically increases UV output compared to other conventional bulbs of equal wattage. Pure quartz material resists solarization and improves the longevity of the bulb. Unique test tube style pure hard quartz sleeve isolates the bulb from water contact preventing thermal shock, broken glass and mercury contamination of the aquarium. This quartz sleeve isolates the bulb to provide an optimal bulb operating temperature of 100 degree F(38 degree C). This higher bulb temperature increases UV output 35% over conventional units without sleeves. Bulb changing is the easiest in the industry. Simply slide the old bulb out and slide the new bulb in. No need to shut down the filter system or turn off the pump. Bulb and ballast connect together with a single 4 pin connector. UV radiation levels can be increased by slowing down the flow rate or increasing the total wattage in the system. UV sterilizers are available from 15 watts up to 240 watts. Tandem mounting will provide proper wattage for any installation requirement. UV sterilization is most effective when used as the final stage of the Lifegard filtration system. It must be understood that micro-organisms reproduce exponentially. The goal is to reduce the micro-organism population to an acceptable level. In certain instances, the wattage may be adequate to eliminate the pathogens flowing through the Sterilizer but the flow rate is too slow to keep up with the total micro-organism population in the aquarium system. In those cases, the flow rate and total wattage must be increased.
1339 -
Overview
Aquarium, The radiation from ultraviolet light at 2537 angstroms provided inside the Lifegard Ultraviolet Sterilizer exerts a lethal effect on micro-organisms. UV light alters genetic material within the cells, which interrupts respiration. UV light, when used properly, is extremely beneficial in destroying disease causing pathogens as they pass through the unit. UV sterilization is an effective method of disease control. Four major factors affect the percent kill of free-floating micro- organisms by UV radiation. (l) Size of organisms. (2) Radiation level. (3) The extent to which UV rays penetrate the water and (4) Contact time in which the micro-organism is exposed to the UV radiation. Pure hard quartz material in the bulb dramatically increases UV output compared to other conventional bulbs of equal wattage. Pure quartz material resists solarization and improves the longevity of the bulb. Unique test tube style pure hard quartz sleeve isolates the bulb from water contact preventing thermal shock, broken glass and mercury contamination of the aquarium. This quartz sleeve isolates the bulb to provide an optimal bulb operating temperature of 100 degree F(38 degree C). This higher bulb temperature increases UV output 35% over conventional units without sleeves. Bulb changing is the easiest in the industry. Simply slide the old bulb out and slide the new bulb in. No need to shut down the filter system or turn off the pump. Bulb and ballast connect together with a single 4 pin connector. UV radiation levels can be increased by slowing down the flow rate or increasing the total wattage in the system. UV sterilizers are available from 15 watts up to 240 watts. Tandem mounting will provide proper wattage for any installation requirement. UV sterilization is most effective when used as the final stage of the Lifegard filtration system. It must be understood that micro-organisms reproduce exponentially. The goal is to reduce the micro-organism population to an acceptable level. In certain instances, the wattage may be adequate to eliminate the pathogens flowing through the Sterilizer but the flow rate is too slow to keep up with the total micro-organism population in the aquarium system. In those cases, the flow rate and total wattage must be increased.
2916 -
Overview
Aquarium, The radiation from ultraviolet light at 2537 angstroms provided inside the Lifegard Ultraviolet Sterilizer exerts a lethal effect on micro-organisms. UV light alters genetic material within the cells, which interrupts respiration. UV light, when used properly, is extremely beneficial in destroying disease causing pathogens as they pass through the unit. UV sterilization is an effective method of disease control. Four major factors affect the percent kill of free-floating micro- organisms by UV radiation. (l) Size of organisms. (2) Radiation level. (3) The extent to which UV rays penetrate the water and (4) Contact time in which the micro-organism is exposed to the UV radiation. Pure hard quartz material in the bulb dramatically increases UV output compared to other conventional bulbs of equal wattage. Pure quartz material resists solarization and improves the longevity of the bulb. Unique test tube style pure hard quartz sleeve isolates the bulb from water contact preventing thermal shock, broken glass and mercury contamination of the aquarium. This quartz sleeve isolates the bulb to provide an optimal bulb operating temperature of 100 degree F(38 degree C). This higher bulb temperature increases UV output 35% over conventional units without sleeves. Bulb changing is the easiest in the industry. Simply slide the old bulb out and slide the new bulb in. No need to shut down the filter system or turn off the pump. Bulb and ballast connect together with a single 4 pin connector. UV radiation levels can be increased by slowing down the flow rate or increasing the total wattage in the system. UV sterilizers are available from 15 watts up to 240 watts. Tandem mounting will provide proper wattage for any installation requirement. UV sterilization is most effective when used as the final stage of the Lifegard filtration system. It must be understood that micro-organisms reproduce exponentially. The goal is to reduce the micro-organism population to an acceptable level. In certain instances, the wattage may be adequate to eliminate the pathogens flowing through the Sterilizer but the flow rate is too slow to keep up with the total micro-organism population in the aquarium system. In those cases, the flow rate and total wattage must be increased.
4434 -
Overview
Aquarium, The radiation from ultraviolet light at 2537 angstroms provided inside the Lifegard Ultraviolet Sterilizer exerts a lethal effect on micro-organisms. UV light alters genetic material within the cells, which interrupts respiration. UV light, when used properly, is extremely beneficial in destroying disease causing pathogens as they pass through the unit. UV sterilization is an effective method of disease control. Four major factors affect the percent kill of free-floating micro- organisms by UV radiation. (l) Size of organisms. (2) Radiation level. (3) The extent to which UV rays penetrate the water and (4) Contact time in which the micro-organism is exposed to the UV radiation. Pure hard quartz material in the bulb dramatically increases UV output compared to other conventional bulbs of equal wattage. Pure quartz material resists solarization and improves the longevity of the bulb. Unique test tube style pure hard quartz sleeve isolates the bulb from water contact preventing thermal shock, broken glass and mercury contamination of the aquarium. This quartz sleeve isolates the bulb to provide an optimal bulb operating temperature of 100 degree F(38 degree C). This higher bulb temperature increases UV output 35% over conventional units without sleeves. Bulb changing is the easiest in the industry. Simply slide the old bulb out and slide the new bulb in. No need to shut down the filter system or turn off the pump. Bulb and ballast connect together with a single 4 pin connector. UV radiation levels can be increased by slowing down the flow rate or increasing the total wattage in the system. UV sterilizers are available from 15 watts up to 240 watts. Tandem mounting will provide proper wattage for any installation requirement. UV sterilization is most effective when used as the final stage of the Lifegard filtration system. It must be understood that micro-organisms reproduce exponentially. The goal is to reduce the micro-organism population to an acceptable level. In certain instances, the wattage may be adequate to eliminate the pathogens flowing through the Sterilizer but the flow rate is too slow to keep up with the total micro-organism population in the aquarium system. In those cases, the flow rate and total wattage must be increased.
5700 -
Overview
Aquarium, The radiation from ultraviolet light at 2537 angstroms provided inside the Lifegard Ultraviolet Sterilizer exerts a lethal effect on micro-organisms. UV light alters genetic material within the cells, which interrupts respiration. UV light, when used properly, is extremely beneficial in destroying disease causing pathogens as they pass through the unit. UV sterilization is an effective method of disease control. Four major factors affect the percent kill of free-floating micro- organisms by UV radiation. (l) Size of organisms. (2) Radiation level. (3) The extent to which UV rays penetrate the water and (4) Contact time in which the micro-organism is exposed to the UV radiation. Pure hard quartz material in the bulb dramatically increases UV output compared to other conventional bulbs of equal wattage. Pure quartz material resists solarization and improves the longevity of the bulb. Unique test tube style pure hard quartz sleeve isolates the bulb from water contact preventing thermal shock, broken glass and mercury contamination of the aquarium. This quartz sleeve isolates the bulb to provide an optimal bulb operating temperature of 100 degree F(38 degree C). This higher bulb temperature increases UV output 35% over conventional units without sleeves. Bulb changing is the easiest in the industry. Simply slide the old bulb out and slide the new bulb in. No need to shut down the filter system or turn off the pump. Bulb and ballast connect together with a single 4 pin connector. UV radiation levels can be increased by slowing down the flow rate or increasing the total wattage in the system. UV sterilizers are available from 15 watts up to 240 watts. Tandem mounting will provide proper wattage for any installation requirement. UV sterilization is most effective when used as the final stage of the Lifegard filtration system. It must be understood that micro-organisms reproduce exponentially. The goal is to reduce the micro-organism population to an acceptable level. In certain instances, the wattage may be adequate to eliminate the pathogens flowing through the Sterilizer but the flow rate is too slow to keep up with the total micro-organism population in the aquarium system. In those cases, the flow rate and total wattage must be increased.
8400 -
Overview
Due to its unique shape, the Lifegard Fluidized Bed Filter is an extremely efficient, high capacity biological filter. Aquatic organisms excrete toxic ammonia as a metabolic waste product, with additional ammonia produced as food and other organic matter breaks down and decomposes. This toxic ammonia (NH3) is converted into another toxic compound nitrite (NO2) by the Nitrosomonas species of bacteria. The nitrite is then converted to a relatively non toxic compound called nitrate (NO3) by the Nitrobacter species of bacteria. This process is known as nitrification. A biological filter is a vessel where nitrification occurs and soluble waste is removed. Beneficial bacteria attach to the media within the Lifegard Fluidized Bed Filter… creating a thin film around the sand grains. Water is pumped up through the unit, lifting the sand into a fluidized bed. The beneficial bacteria attached to the media draw in dissolved wastes (ammonia and nitrite) and oxygen supplied by exclusive water fall device and other required nutrients from the passing water converts them to relatively harmless nitrate. The sand grains are in continual free fall through the water, resulting in an excellent transfer capability between the liquid and the bacterial film on the media. The enormously high surface area combined with this excellent transfer capability creates the perfect habitat for bacterial growth. In addition, the sand grains bump into each other frequently, knocking off excess debris and providing a self cleaning function which allows new areas for bacterial growth. The Lifegard Fluidized Bed Filter has been tested and proven to supply the highest level of effluent water quality and will respond quickly and efficiently to severe changes in ammonia levels caused by over feeding or the addition of too many fish at one time. To obtain highest water quality a Lifegard Fluidized Bed Filter should be part of the system.
429 -
Overflow
- High flow mechanical filter with 2″ suction and 2″ discharge.
- Small footprint.
- To convert to a chemical filter remove the cartridge and place carbon in a filter bag inside the chamber.
1602 -
-
-
Angular shaped media collide frequently, knocking off debris which creates new area for bacterial growth to occur. Enormous surface area for bacterial growth. Easily fluidized with a small power head pump.
54 -
Overview
Commercial sized M-Series Mechanical and Chemical Modules are available to meet any size application including: Custom Aquarium Installations, Central filtration Systems, Hatcheries, Reservoirs, Mixing Tanks, Retail Store Displays, Livestock Importers, Public Aquariums, Aquaculture and Mariculture Installations. UV Sterilizers are also available, see Ultraviolet Sterilizer Modules.
1368 -
Overview
Commercial sized M-Series Mechanical and Chemical Modules are available to meet any size application including: Custom Aquarium Installations, Central filtration Systems, Hatcheries, Reservoirs, Mixing Tanks, Retail Store Displays, Livestock Importers, Public Aquariums, Aquaculture and Mariculture Installations. UV Sterilizers are also available, see Ultraviolet Sterilizer Modules.
2445 -
Overview
Commercial sized M-Series Mechanical and Chemical Modules are available to meet any size application including: Custom Aquarium Installations, Central filtration Systems, Hatcheries, Reservoirs, Mixing Tanks, Retail Store Displays, Livestock Importers, Public Aquariums, Aquaculture and Mariculture Installations. UV Sterilizers are also available, see Ultraviolet Sterilizer Modules.
3375 -
-
-
Overview
Single capacity filter features the Lifegard exclusive combination mechanical and chemical cartridge. Internal carbon chamber has retainer screen to prevent carbon from escaping into system. Carbon can be easily rinsed while inside chamber. Double and triple capacity units feature mechanical cartridge only. Water is forced through the filter pleats under pressure, trapping particles from 20 microns down to 5 microns on the outside of the cartridge. Economical replaceable pleats eliminate costly cartridge replacement. Highest quality PVC molded parts.
512 -
Overview
Single capacity filter features the Lifegard exclusive combination mechanical and chemical cartridge. Internal carbon chamber has retainer screen to prevent carbon from escaping into system. Carbon can be easily rinsed while inside chamber. Double and triple capacity units feature mechanical cartridge only. Water is forced through the filter pleats under pressure, trapping particles from 20 microns down to 5 microns on the outside of the cartridge. Economical replaceable pleats eliminate costly cartridge replacement. Highest quality PVC molded parts.
601 -
Overview
Single capacity filter features the Lifegard exclusive combination mechanical and chemical cartridge. Internal carbon chamber has retainer screen to prevent carbon from escaping into system. Carbon can be easily rinsed while inside chamber. Double and triple capacity units feature mechanical cartridge only. Water is forced through the filter pleats under pressure, trapping particles from 20 microns down to 5 microns on the outside of the cartridge. Economical replaceable pleats eliminate costly cartridge replacement. Highest quality PVC molded parts.
629 -
Overview
Recommended aquarium sizes are approximate. In many cases, single, double and triple capacity modules can be used with great success in higher volume applications. Single capacity filter features the Lifegard exclusive combination mechanical and chemical cartridge. Internal carbon chamber has retainer screen to prevent carbon from escaping into system. Carbon can be easily rinsed while inside chamber. Double and triple capacity units feature mechanical cartridge only. Water is forced through the filter pleats under pressure, trapping particles from 20 microns down to 5 microns on the outside of the cartridge. Economical replaceable pleats eliminate costly cartridge replacement. Highest quality PVC molded parts.
374 -
Overview
Recommended aquarium sizes are approximate. In many cases, single, double and triple capacity modules can be used with great success in higher volume applications. Single capacity filter features the Lifegard exclusive combination mechanical and chemical cartridge. Internal carbon chamber has retainer screen to prevent carbon from escaping into system. Carbon can be easily rinsed while inside chamber. Double and triple capacity units feature mechanical cartridge only. Water is forced through the filter pleats under pressure, trapping particles from 20 microns down to 5 microns on the outside of the cartridge. Economical replaceable pleats eliminate costly cartridge replacement. Highest quality PVC molded parts.
449 -
Overview
Recommended aquarium sizes are approximate. In many cases, single, double and triple capacity modules can be used with great success in higher volume applications. Single capacity filter features the Lifegard exclusive combination mechanical and chemical cartridge. Internal carbon chamber has retainer screen to prevent carbon from escaping into system. Carbon can be easily rinsed while inside chamber. Double and triple capacity units feature mechanical cartridge only. Water is forced through the filter pleats under pressure, trapping particles from 20 microns down to 5 microns on the outside of the cartridge. Economical replaceable pleats eliminate costly cartridge replacement. Highest quality PVC molded parts.
543 -
Overview
Recommended aquarium sizes are approximate. In many cases, single, double and triple capacity modules can be used with great success in higher volume applications. Single capacity filter features the Lifegard exclusive combination mechanical and chemical cartridge. Internal carbon chamber has retainer screen to prevent carbon from escaping into system. Carbon can be easily rinsed while inside chamber. Double and triple capacity units feature mechanical cartridge only. Water is forced through the filter pleats under pressure, trapping particles from 20 microns down to 5 microns on the outside of the cartridge. Economical replaceable pleats eliminate costly cartridge replacement. Highest quality PVC molded parts.
283 -
Overview
Recommended aquarium sizes are approximate. In many cases, single, double and triple capacity modules can be used with great success in higher volume applications. Single capacity filter features the Lifegard exclusive combination mechanical and chemical cartridge. Internal carbon chamber has retainer screen to prevent carbon from escaping into system. Carbon can be easily rinsed while inside chamber. Double and triple capacity units feature mechanical cartridge only. Water is forced through the filter pleats under pressure, trapping particles from 20 microns down to 5 microns on the outside of the cartridge. Economical replaceable pleats eliminate costly cartridge replacement. Highest quality PVC molded parts.
324 -
Overview
Recommended aquarium sizes are approximate. In many cases, single, double and triple capacity modules can be used with great success in higher volume applications. Single capacity filter features the Lifegard exclusive combination mechanical and chemical cartridge. Internal carbon chamber has retainer screen to prevent carbon from escaping into system. Carbon can be easily rinsed while inside chamber. Double and triple capacity units feature mechanical cartridge only. Water is forced through the filter pleats under pressure, trapping particles from 20 microns down to 5 microns on the outside of the cartridge. Economical replaceable pleats eliminate costly cartridge replacement. Highest quality PVC molded parts.
394 -
-
-
-
Overflow
- High flow mechanical filter with 2″ suction and 2″ discharge.
- Small footprint.
- To convert to a chemical filter remove the cartridge and place carbon in a filter bag inside the chamber.
1102 -
Overflow
- High flow mechanical filter with 2″ suction and 2″ discharge.
- Small footprint.
- To convert to a chemical filter remove the cartridge and place carbon in a filter bag inside the chamber.
1449 -
-
-
Overview
- Splash Boot creates water resistant seal around electrical connection
- Unique 4-pin connector design for easy bulb replacement without shutting down system
- UV Bulb of highest quality pure hard quartz material allows maximum UV transmission and longer bulb life. End cap wire design drops bulb further into unit for maximum output and keeps heat away from sealing area
- 15, 25 or 40 Watt UL Listed Ballast (230V, 50Hz Ballast available
- Compression Coupling and gasket seals quartz sleeve to cap
- Test Tube style quartz sleeve isolates UV bulb from water contact allowing it to operate at the optimum bulb temperature for maximum UV output. Highest quality pure hard quartz material allows maximum UV transmission
- Replaceable Internal Overflow Pipe automatically vents air from chamber and directs 100% of the water flow past the UV light
- Sleeve Guide guides quartz sleeve into proper position for accurate assembly
- Replaceable Inner protective Sleeve protects outer housing from long term UV damage. Acts as an internal reflector maximizing UV efficiency
- Modular Construction allows simple connection to any Lifegard Modular Filter System or outside cannister filter
- Solid Cap features Clear View Port to allow visible light (no UV) to pass through and indicate bulb is operating
359 -
Overview
- Splash Boot creates water resistant seal around electrical connection
- Unique 4-pin connector design for easy bulb replacement without shutting down system
- UV Bulb of highest quality pure hard quartz material allows maximum UV transmission and longer bulb life. End cap wire design drops bulb further into unit for maximum output and keeps heat away from sealing area
- 15, 25 or 40 Watt UL Listed Ballast (230V, 50Hz Ballast available
- Compression Coupling and gasket seals quartz sleeve to cap
- Test Tube style quartz sleeve isolates UV bulb from water contact allowing it to operate at the optimum bulb temperature for maximum UV output. Highest quality pure hard quartz material allows maximum UV transmission
- Replaceable Internal Overflow Pipe automatically vents air from chamber and directs 100% of the water flow past the UV light
- Sleeve Guide guides quartz sleeve into proper position for accurate assembly
- Replaceable Inner protective Sleeve protects outer housing from long term UV damage. Acts as an internal reflector maximizing UV efficiency
- Modular Construction allows simple connection to any Lifegard Modular Filter System or outside cannister filter
- Solid Cap features Clear View Port to allow visible light (no UV) to pass through and indicate bulb is operating
244 -
Overview
- Splash Boot creates water resistant seal around electrical connection
- Unique 4-pin connector design for easy bulb replacement without shutting down system
- UV Bulb of highest quality pure hard quartz material allows maximum UV transmission and longer bulb life. End cap wire design drops bulb further into unit for maximum output and keeps heat away from sealing area
- 15, 25 or 40 Watt UL Listed Ballast (230V, 50Hz Ballast available
- Compression Coupling and gasket seals quartz sleeve to cap
- Test Tube style quartz sleeve isolates UV bulb from water contact allowing it to operate at the optimum bulb temperature for maximum UV output. Highest quality pure hard quartz material allows maximum UV transmission
- Replaceable Internal Overflow Pipe automatically vents air from chamber and directs 100% of the water flow past the UV light
- Sleeve Guide guides quartz sleeve into proper position for accurate assembly
- Replaceable Inner protective Sleeve protects outer housing from long term UV damage. Acts as an internal reflector maximizing UV efficiency
- Modular Construction allows simple connection to any Lifegard Modular Filter System or outside cannister filter
- Solid Cap features Clear View Port to allow visible light (no UV) to pass through and indicate bulb is operating
279 -
Overview
- Splash Boot creates water resistant seal around electrical connection
- Unique 4-pin connector design for easy bulb replacement without shutting down system
- UV Bulb of highest quality pure hard quartz material allows maximum UV transmission and longer bulb life. End cap wire design drops bulb further into unit for maximum output and keeps heat away from sealing area
- 15, 25 or 40 Watt UL Listed Ballast (230V, 50Hz Ballast available
- Compression Coupling and gasket seals quartz sleeve to cap
- Test Tube style quartz sleeve isolates UV bulb from water contact allowing it to operate at the optimum bulb temperature for maximum UV output. Highest quality pure hard quartz material allows maximum UV transmission
- Replaceable Internal Overflow Pipe automatically vents air from chamber and directs 100% of the water flow past the UV light
- Sleeve Guide guides quartz sleeve into proper position for accurate assembly
- Replaceable Inner protective Sleeve protects outer housing from long term UV damage. Acts as an internal reflector maximizing UV efficiency
- Modular Construction allows simple connection to any Lifegard Modular Filter System or outside cannister filter
- Solid Cap features Clear View Port to allow visible light (no UV) to pass through and indicate bulb is operating
199
- 1
- 2